Vernier Calliper Stainless Steel Manufacturer,Supplier and Exporter in India
Product Code : SCL-ME-12397
The Vernier Calliper Stainless Steel is a precision measuring instrument used for measuring external dimensions, internal dimensions, depth, and small object thickness in laboratory practicals. It is suitable for schools, colleges, physics laboratories, STEM classrooms, engineering workshops, and students learning accurate manual measurement techniques.
Product Description
The School Equipments Vernier Calliper Stainless Steel is a manual measuring tool for practical science and metrology lessons. It helps students learn how to read a main scale and vernier scale, compare measurements, identify zero error, and record dimensions with better precision than a standard ruler.
This stainless steel calliper is useful for physics experiments, workshop measurement tasks, dimensional inspection, and STEM model evaluation. It can measure outside diameter, inside diameter, step dimensions, and depth when used correctly. Exact measuring range, least count, jaw design, and packing details should be confirmed before final publication or tender submission.
Key Features
- Stainless steel construction: Suitable for repeated school laboratory and workshop handling.
- Manual vernier reading: Helps students understand main scale, vernier scale, least count, and zero error.
- Multiple measurement modes: Supports external, internal, step, and depth measurement where the supplied model includes the required jaws and depth rod.
- Physics practical utility: Useful for measuring cylinders, rods, tubes, blocks, small components, and experiment samples.
- No battery required: Operates mechanically without electronic display, charging, or cells.
- Reusable measuring instrument: Suitable for classroom demonstrations and supervised student practicals.
- STEM-ready tool: Supports measurement, model making, dimensional comparison, and workshop skill development.
Technical Specifications
|
Specification |
Detail |
|
Product Name |
Vernier Calliper Stainless Steel |
|
Brand |
School Equipments |
|
Product Category |
Lab Equipment / Measuring Equipment / Manual Precision Measuring Instrument |
|
Primary Keyword |
Vernier Calliper Stainless Steel |
|
Secondary Keywords |
stainless steel vernier calliper, manual vernier caliper, school lab measuring instrument, internal external depth measurement, physics measurement tool, STEM measuring equipment |
|
Material |
Stainless steel |
|
Scale Type |
Main scale and vernier scale |
|
Display Type |
Manual analogue reading |
|
Power Requirement |
No battery required |
What's Included in the Kit
- 1 Vernier Calliper Stainless Steel
- Protective case or pouch
- Instruction sheet
- Calibration certificate: not included unless specified in the quotation
Applications / Uses
- Measuring external diameter, thickness, and length of small objects.
- Measuring internal diameter of tubes, rings, and hollow components.
- Measuring depth of cavities, holes, and containers when the model includes a depth rod.
- Teaching least count, zero error, main-scale reading, and vernier-scale reading.
- Supporting practical work in measuring equipment lessons.
- Using with broader school laboratory equipment for routine dimensional measurement.
- Pairing with the Electronic Digital Caliper for comparing manual and digital measurement methods.
- Adding measurement practice to STEM lab kit activities.
How to Use the Vernier Calliper Stainless Steel
- Clean the jaws and the object before measurement.
- Close the jaws gently and check for zero error.
- Place the object between the outside jaws for external measurement.
- Use the inside jaws for internal diameter measurement where applicable.
- Use the depth rod for depth measurement where included in the model.
- Read the main scale value just before the zero mark of the vernier scale.
- Find the vernier division that aligns with the main scale and add it to the main scale reading.
Safety note: Do not force the jaws, drop the calliper, or use it on moving machinery. Use the instrument only for measurement and store it safely after practical work.
Care & Maintenance
- Wipe the calliper clean and dry after every laboratory session.
- Store it in a protective case to prevent jaw damage and scale scratches.
- Keep the sliding jaw free from dust, rust, and rough handling.
- Do not expose the instrument to corrosive chemicals or moisture during storage.
Why Choose School Equipments
School Equipments manufactures and exports scientific laboratory instruments, lab experiment setups, science kits, mathematics kits, didactic models, and STEM models for educational institutions. The brand supplies measuring tools, physics apparatus, STEM products, and general laboratory equipment for schools, colleges, and procurement projects.
The Vernier Calliper Stainless Steel supports practical measurement training by helping students learn manual precision reading rather than depending only on digital displays. Buyers can source it with related measuring instruments, lab tools, physics apparatus, and school science equipment from School Equipments.
Frequently Asked Questions
What is a Vernier Calliper Stainless Steel used for?
A Vernier Calliper Stainless Steel is used to measure external dimensions, internal dimensions, depth, and thickness in school laboratory and STEM measurement activities.
Is this a manual or digital calliper?
This product is described as a manual vernier calliper. It uses a main scale and vernier scale rather than an LCD display.
Does a vernier calliper need a battery?
No, a manual vernier calliper does not need a battery. Students read the measurement directly from the engraved scales.
What should buyers confirm before ordering?
Buyers should confirm measuring range, least count, jaw type, depth rod, storage case, calibration certificate requirement, and tender-specific inspection details.
Can students use this in physics practicals?
Yes, it is suitable for supervised physics practicals involving measurement of diameter, thickness, length, depth, and small laboratory components.
How is a manual vernier calliper different from a digital caliper?
A manual vernier calliper requires scale reading and least-count calculation. A digital caliper displays the value electronically and is easier to read but depends on battery power.
For related products, explore the Measuring Equipment category from School Equipments.
Suggested Image ALT Text: Vernier Calliper Stainless Steel manual measuring instrument for school physics and STEM laboratory practicals.
